top of page

7470 Slice Recovery Chamber

  • Six slice holding chambers

  • Integrated gas bubbler

  • Condensate flow eliminates the risk of osmotic shock

  • Bath Thermistor for fast feedback

  • Thermistor calibrated to ± 2° C

  • Proportional Integral & Derivative Control algorithm

  • Overheat Alarm

  • Set Temperature Resolution: 0.5°C

  • Temperature Resolution: 0.1°C

  • Temperature Probe Accuracy: +/- 0.5°C

  • Temperature Range: 25°C to 45°C

Details

Simple and Inexpensive!

The Model 7470 Temperature-controlled Slice Holding chamber, has been developed to accompany the Campden Instruments range of tissue slicers.

The 7470 has been developed according to the principles described in the Plymouth Microelectrode Handbook (Gibb, A.J. and Edwards, F.A., 1994. Patch clamp recording from cells in sliced tissues. In Microelectrode Techniques: The Plymouth Workshop Handbook). The chamber was designed to hold and maintain tissue slices in six sub-chambers at physiological temperatures with an aeration supply to allow recovery from slicing as well as incubation during the experimental day (10-12 hrs).

 

The Proportional Integral & Derivative (PID) controlled heating element is integrated into the stainless steel bath bottom plate. All metal components are manufactured from high-grade stainless steel to remove the risk of contamination of the slice. Temperature feedback is via a thermistor probe attached to the bath wall at the same water as the specimen holder rings. We have also designed the chamber to reduce the risk of thermal/osmotic shock by ensuring the condensation on the lid does not drip back down on to the slice. The aeration pathway has been arranged so that the slice is not disturbed by the bubbles and the created fluid current helps retain the slices within the sub-chamber.

Further Information

Our Vibrotomes

5100mz.jpg

5100mz

The New 5100mz shares the User interface with the premium 7000smz-2, placing a wide range of adjustable parameters at the user’s fingertips.

5100mz.jpg

5100mz-Plus

The 5100mz-Plus is perfect for those who need to keep slices viable for longer e.g. for electrophysiological field recordings. The user can calibrate the Z-axis deflection of the blade to 2 µm with the adjustable blade holder and “Opti-cal” Calibration device

7000smz-2%252520high%252520res_edited_ed

7000smz-2

Our top of the range high precision, vibrating microtome, this is the finest slicer in the world for preparations for visual patch clamping. Cold light and scope or magnifier are optional.

StuartGreenhillCropped_edited.jpg

Stuart Greenhill, PhD,

Aston University

Our laboratory uses both animal and human tissue in acute and organotypic culture brain slice experiments. We have two 7000smz-2 vibrotomes in daily use which form the backbone of our slice preparations – the reliability and repeatability provided by the slicer’s Z-axis stability and calibration mechanism means that our preparations get off to the best possible start. The 7000smz-2 produces the highest quality brain slices of any vibrotome I have used, allowing us to generate in vivo-like oscillations in slice preparations. On top of this the service and support from Campden has been second to none.